Installation Restoration Program. Site Investigation Report, Volume 2. 182 Airlift Wing, Illinois Air National Guard, Greater Peoria Regional Airport, Peoria, Illinois

Installation Restoration Program. Site Investigation Report, Volume 2. 182 Airlift Wing, Illinois Air National Guard, Greater Peoria Regional Airport, Peoria, Illinois
Author:
Publisher:
Total Pages: 369
Release: 1996
Genre:
ISBN:

Download Installation Restoration Program. Site Investigation Report, Volume 2. 182 Airlift Wing, Illinois Air National Guard, Greater Peoria Regional Airport, Peoria, Illinois Book in PDF, Epub and Kindle

Site Investigation Report, Illinois Air National Guard, 182nd Airlift Wing, Greater Peoria Regional Airport, Peoria, Illinois, Volume II - Appendices A-K. This is the second volume of a two volume Site Investigation Report. Three sites (Site 1 - Septic System Filter Beds Site 2 Grassy Area Facility Boundary East of the Aircraft Apron, and Site 3 - Grass Area West of Aircraft Apron and East of Fuel Truck Parking) were investigated under the Installation Restoration Program. Soil and groundwater samples were collected and analyzed. A Remedial Investigation was recommended for the soils at Site 1. No further action was recommended for Site 2 and the soils at Site 3. A groundwater investigation was recommended to identify the source of low concentrations of VOCs in the groundwater.

Installation Restoration Program. Site Investigation Report, Volume 1. 182 Airlift Wing, Illinois Air National Guard, Greater Peoria Regional Airport, Peoria, Illinois

Installation Restoration Program. Site Investigation Report, Volume 1. 182 Airlift Wing, Illinois Air National Guard, Greater Peoria Regional Airport, Peoria, Illinois
Author:
Publisher:
Total Pages: 243
Release: 1996
Genre:
ISBN:

Download Installation Restoration Program. Site Investigation Report, Volume 1. 182 Airlift Wing, Illinois Air National Guard, Greater Peoria Regional Airport, Peoria, Illinois Book in PDF, Epub and Kindle

Site Investigation Report, Illinois Air National Guard, 182nd Airlift Wing, Greater Peoria Regional Airport, Peoria, Illinois, Volume I - Text. This is the first volume of a two volume Site Investigation Report. Three sites (Site 1 - Septic System Filter Beds, Site 2 - Grassy Area Along Facility Boundary East of the Aircraft Apron, and Site 3 - Grass Area West of Aircraft Apron and East of Fuel Truck Parking) were investigated under the Installation Restoration Program. Soil and groundwater samples were collected and analyzed. A Remedial Investigation was recommended for the soils at Site 1. No further action was recommended for Site 2 and the soils at Site 3. A groundwater investigation was recommended to identify the source of low concentrations of VOCs in the groundwater.

Installation Restoration Program

Installation Restoration Program
Author: Illinois. Air National Guard. 182nd Airlift Wing
Publisher:
Total Pages:
Release: 2001
Genre: Hazardous waste site remediation
ISBN:

Download Installation Restoration Program Book in PDF, Epub and Kindle

Installation Restoration Program. Site Investigation Report. Volume 2: Appendices. 183rd Fighter Group, Illinois Air National Guard, Capital Airport, Springfield, Illinois

Installation Restoration Program. Site Investigation Report. Volume 2: Appendices. 183rd Fighter Group, Illinois Air National Guard, Capital Airport, Springfield, Illinois
Author: MARTIN MARIETTA ENERGY SYSTEMS INC OAK RIDGE TN.
Publisher:
Total Pages: 755
Release: 1996
Genre:
ISBN:

Download Installation Restoration Program. Site Investigation Report. Volume 2: Appendices. 183rd Fighter Group, Illinois Air National Guard, Capital Airport, Springfield, Illinois Book in PDF, Epub and Kindle

Site Investigation Report, Illinois Air National Guard, 183rd Fighter Group, Capital Airport, Springfield, Illinois, Volume II - Appendices. This is the second volume of a two volume site investigation report. Two sites (Site 1 - POL Storage Area, and Site 2 - Old Fire Training Area) were investigated under the Installation Restoration Program. Soil and groundwater samples were collected from both sites and analyzed. Surface water and sediment samples were collected from Site 2 and analyzed. Monitoring of the dissolved hydrocarbon plume using existing monitoring wells was recommended for Site 1. A Remedial Investigation to define the nature and extent of soil and groundwater contamination was recommended for Site 2.

Government Reports Annual Index

Government Reports Annual Index
Author:
Publisher:
Total Pages: 1192
Release: 1991
Genre: Government publications
ISBN:

Download Government Reports Annual Index Book in PDF, Epub and Kindle

Installation Restoration Program, Technical Memorandum for Field Investigation at IRP Sites No. 1 and No. 2, Vol 1, 183rd Fighter Wing, Illinois Air National Guard, Capital Municipal Airport, Springfield, Illinois

Installation Restoration Program, Technical Memorandum for Field Investigation at IRP Sites No. 1 and No. 2, Vol 1, 183rd Fighter Wing, Illinois Air National Guard, Capital Municipal Airport, Springfield, Illinois
Author:
Publisher:
Total Pages: 67
Release: 1997
Genre:
ISBN:

Download Installation Restoration Program, Technical Memorandum for Field Investigation at IRP Sites No. 1 and No. 2, Vol 1, 183rd Fighter Wing, Illinois Air National Guard, Capital Municipal Airport, Springfield, Illinois Book in PDF, Epub and Kindle

The Installation Restoration Program was initiated by the Air National Guard (ANG) to evaluate potential contamination to the environment caused by past practices at its installations. Two sites were identified at Capital Municipal Airport during the 1990 Preliminary Assessment; the Petroleum, Oils and Lubricants Storage Area (Site 1) and the Old Fire Training Area (Site 2). Information gathered during a 1996 Site Investigation on both sites and 1995 Site Investigation Addendum for Site 2 did not provide adequate information for decision-making. This Field Investigation was designed to fill data gaps. The Tech Memo recommends Site 1 proceed to a No Further Action Decision Document, and Site 2 proceed to an Engineering Evaluation/Cost Analysis (EE/CA). No further field effort is necessary to complete the EE/CA. Vol 1 contains the main text of the report. Vol 2 contains the supporting data.

Installation Restoration Program. Preliminary Assessment: 182 Tactical Air Support Group, Illinois Air National Guard, Peoria, Illinois

Installation Restoration Program. Preliminary Assessment: 182 Tactical Air Support Group, Illinois Air National Guard, Peoria, Illinois
Author:
Publisher:
Total Pages: 117
Release: 1990
Genre:
ISBN:

Download Installation Restoration Program. Preliminary Assessment: 182 Tactical Air Support Group, Illinois Air National Guard, Peoria, Illinois Book in PDF, Epub and Kindle

Preliminary Assessment of suspected hazardous waste sites at the Illinois Air National Guard, Peoria, Illinois. The study was conducted under the Air National Guard's Installation Restoration Program.

Installation Restoration Program Site Investigation Report; 183rd Fighter Group, Illinois Air National Guard, Capital Airport, Springfield, Illinois

Installation Restoration Program Site Investigation Report; 183rd Fighter Group, Illinois Air National Guard, Capital Airport, Springfield, Illinois
Author: Earth technology corp oak ridge tn
Publisher:
Total Pages: 178
Release: 1996
Genre:
ISBN:

Download Installation Restoration Program Site Investigation Report; 183rd Fighter Group, Illinois Air National Guard, Capital Airport, Springfield, Illinois Book in PDF, Epub and Kindle

This Site Investigation (SI) Report documents activities The Earth Technology Corporation performed at the Illinois Air National Guard (ILANG), 183rd Fighter Group (FG), Capital Airport, Springfield, Illinois under the U.S. Department of Defense Installation Restoration Program. Two sites, Site 1 - Petroleum, Oil, and Lubricant (POL) Storage Area and Site 2 - Old Fire Training Area (FTA), were identified at ILANG, Capital Airport during the Preliminary Assessment (PA) begun by the Dynamac Corporation through the Hazardous Materials Technical Center and completed by Science and Technology in May 1990. Site 1 is located within the base boundaries, while Site 2 is located off-base on Springfield Airport Authority (SAA) property. The SI was conducted to: Confirm the presence or absence of contamination at the sites; Identify the sources and nature of contamination at the sites; Provide a preliminary assessment of the extent, magnitude, and movement of contamination; identify the potential threat of contamination to human health or the environment.